系统运维 1、查看message日志;查看是否有error bash-3.2#moremessagesJul2218:51:46sunm4k_2fmd:[ID377184daemon.error]SUNW-MSG-ID:SUN4U-8000-2S,TYPE:Fault,VER:1,SEVERITY:MajorJul2218:51:46sunm4k_2EVENT-TIME:20Jul2218:51:46sunm4k_2PLATFORM:SUNW,SPARC-Enterprise,CSN:BDF1115195

Solaris简单系统巡检,日志查看

系统运维

1、查看message日志;查看是否有error

bash-3.2# more messages
Jul 22 18:51:46 sunm4k_2 fmd: [ID 377184 daemon.error] SUNW-MSG-ID: SUN4U-8000-2S, TYPE: Fault, VER: 1, SEVERITY: Major
Jul 22 18:51:46 sunm4k_2 EVENT-TIME: 20
Jul 22 18:51:46 sunm4k_2 PLATFORM: SUNW,SPARC-Enterprise, CSN: BDF1115195, HOSTNAME: sunm4k_2
Jul 22 18:51:46 sunm4k_2 SOURCE: cpumem-diagnosis, REV: 1.7
Jul 22 18:51:46 sunm4k_2 EVENT-ID: ecf24522-5df2-ef85-8ead-a0af51b30d08
Jul 22 18:51:46 sunm4k_2 DESC: The number of correctable errors associated with this memory module has exceeded acceptable levels.
Jul 22 18:51:46 sunm4k_2 AUTO-RESPONSE: Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.
Jul 22 18:51:46 sunm4k_2 IMPACT: Total system memory capacity has been reduced.
Jul 22 18:51:46 sunm4k_2 REC-ACTION: Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at http://sun.
com/msg/SUN4U-8000-2S for the latest service procedures and policies regarding this diagnosis.

2、prtdiag ;注意查看status

bash-3.2# prtdiag -v
System Configuration:  Oracle Corporation  sun4u SPARC Enterprise M4000 Server
System clock frequency: 1012 MHz
Memory size: 65536 Megabytes

==================================== CPUs ====================================

      CPU                 CPU                         Run    L2$    CPU   CPU 
LSB   Chip                 ID                         MHz     MB    Impl. Mask
---   ----  ----------------------------------------  ----   ---    ----- ----
 00     0      0,   1,   2,   3,   4,   5,   6,   7   2530   5.5        7  161
 00     1      8,   9,  10,  11,  12,  13,  14,  15   2530   5.5        7  161
 00     2     16,  17,  18,  19,  20,  21,  22,  23   2530   5.5        7  161
 00     3     24,  25,  26,  27,  28,  29,  30,  31   2530   5.5        7  161

============================ Memory Configuration ============================

       Memory  Available           Memory     DIMM    # of  Mirror  Interleave
LSB    Group   Size                Status     Size    DIMMs Mode    Factor    
---    ------  ------------------  -------    ------  ----- ------- ----------
 00    A        32768MB            okay       2048MB     16 no       8-way
 00    B        32768MB            okay       2048MB     16 no       8-way

========================= IO Devices =========================

    IO                                                Lane/Frq                                                       
LSB Type  LPID   RvID,DvID,VnID       BDF       State Act,  Max   Name                           Model               
--- ----- ----   ------------------   --------- ----- ----------- ------------------------------ --------------------
    Logical Path
    ------------
00  PCIe  0      bc, 8532, 10b5       2,  0,  0  okay     8,    8  pci-pciexclass,060400          N/A                 
    /pci@0,600000/pci@0                                                                                 

00  PCIe  0      bc, 8532, 10b5       3,  8,  0  okay     8,    8  pci-pciexclass,060400          N/A                 
    /pci@0,600000/pci@0/pci@8                                                                           

00  PCIe  0      bc, 8532, 10b5       3,  9,  0  okay     1,    8  pci-pciexclass,060400          N/A                 
    /pci@0,600000/pci@0/pci@9                                                                           

00  PCIx  0       8,  125, 1033       4,  0,  0  okay   100,  133  pci-pciexclass,060400          N/A                 
    /pci@0,600000/pci@0/pci@8/pci@0                                                                     

00  PCIx  0       8,  125, 1033       4,  0,  1  okay    --,  133  pci-pciexclass,060400          N/A                 
    /pci@0,600000/pci@0/pci@8/pci@0,1                                                                   

00  PCIx  0       2,   50, 1000       5,  1,  0  okay    --,  133  scsi-pci1000,50                LSI,1064            
    /pci@0,600000/pci@0/pci@8/pci@0/scsi@1                                                              

00  PCIx  0      10, 1648, 14e4       5,  2,  0  okay    --,  133  network-pci14e4,1648           N/A                 
    /pci@0,600000/pci@0/pci@8/pci@0/network@2                                                           

00  PCIx  0      10, 1648, 14e4       5,  2,  1  okay    --,  133  network-pci14e4,1648           N/A                 
    /pci@0,600000/pci@0/pci@8/pci@0/network@2,1                                                         

00  PCIe  1       1, abcd, 108e       2,  0,  0  okay     8,    8  network-pciex108e,abcd         SUNW,pcie-qgc       
    /pci@1,700000/network@0                                                                             

00  PCIe  1       1, abcd, 108e       2,  0,  1  okay     8,    8  network-pciex108e,abcd         SUNW,pcie-qgc       
    /pci@1,700000/network@0,1                                                                           

00  PCIe  1       1, abcd, 108e       2,  0,  2  okay     8,    8  network-pciex108e,abcd         SUNW,pcie-qgc       
    /pci@1,700000/network@0,2                                                                           

00  PCIe  1       1, abcd, 108e       2,  0,  3  okay     8,    8  network-pciex108e,abcd         SUNW,pcie-qgc       
    /pci@1,700000/network@0,3                                                                           

00  PCIe  2       3, 2432, 1077       2,  0,  0  okay     4,    4  SUNW,qlc-pciex1077,2432        QLE2462             
    /pci@2,600000/SUNW,qlc@0                                                                            

00  PCIe  2       3, 2432, 1077       2,  0,  1  okay     4,    4  SUNW,qlc-pciex1077,2432        QLE2462             
    /pci@2,600000/SUNW,qlc@0,1                                                                          

00  PCIe  3       3, 2432, 1077       2,  0,  0  okay     4,    4  SUNW,qlc-pciex1077,2432        QLE2462             
    /pci@3,700000/SUNW,qlc@0                                                                            

00  PCIe  3       3, 2432, 1077       2,  0,  1  okay     4,    4  SUNW,qlc-pciex1077,2432        QLE2462             
    /pci@3,700000/SUNW,qlc@0,1                                                                          


==================== Hardware Revisions ====================

System PROM revisions:
----------------------

OBP 4.33.5.a 2012/01/13 15:05


=================== Environmental Status ===================

Mode switch is in LOCK mode 

=================== System Processor Mode ===================

3、fmadm; 查看输出,正常情况下是无输出的;

bash-3.2# fmadm faulty
--------------- ------------------------------------  -------------- ---------
TIME            EVENT-ID                              MSG-ID         SEVERITY
--------------- ------------------------------------  -------------- ---------
Jul 22 18:51:46 ecf24522-5df2-ef85-8ead-a0af51b30d08  SUN4U-8000-2S  Major     

Host        : sunm4k_2
Platform    : SUNW,SPARC-Enterprise     Chassis_id  : BDF1115195
Product_sn  : 

Fault class : fault.memory.dimm 95%
Affects     : mem:///unum=/MBU_A/MEMB3/MEM2A
                  faulted but still in service
FRU         : mem:///unum=/MBU_A/MEMB3/MEM2A 95%
                  faulty
Serial ID.  : 522A45BE:M3 93T5660QZA-CE6 

Description : The number of correctable errors associated with this memory
              module has exceeded acceptable levels.

Response    : Pages of memory associated with this memory module have been
              removed from service, up to a limit which has now been reached.

Impact      : Total system memory capacity has been reduced.

Action      : Use 'fmadm faulty' to provide a more detailed view of this event.
              Please refer to the associated reference document at
              http://sun.com/msg/SUN4U-8000-2S for the latest service
              procedures and policies regarding this diagnosis.

更多关于云服务器域名注册虚拟主机的问题,请访问西部数码官网:www.west.cn

延伸 · 阅读

精彩推荐
  • SolarisSolaris系统硬盘分区知识

    Solaris系统硬盘分区知识

    Solaris 下,一个磁盘包含8个分区,标记为0-7。此信息可以通过format命令,然后选择一个硬盘来看到,例如,在我自己的系统中(Solaris9,Ultra60),显示出来的信...

    Solaris教程网6252019-11-18
  • SolarisSolaris设置ADSL拨号上网

    Solaris设置ADSL拨号上网

    Solaris设置ADSL拨号上网...

    Solaris教程网2722019-11-22
  • Solarissolaris下VNC的安裝方法

    solaris下VNC的安裝方法

    solaris下VNC的安裝方法,有需要的朋友可以参考一下。 ...

    solaris教程网6232019-11-19
  • SolarisSolaris系统下配置MPXIO

    Solaris系统下配置MPXIO

    用的LSI的存储 和普安的存储 SUN V245平台+LPE11002 或者Qlogic QLE2460 环境SUN的V245 +LSI 3994 想测试下 LSI的存储在Solaris下的路径冗余,因为用LSI带的RDAC装完系统就...

    Solaris教程网3952019-11-11
  • SolarisSolaris中对tar.z进行安装卸载详解

    Solaris中对tar.z进行安装卸载详解

    今天小编将要为大家带来的是Solaris中对tar.z进行安装卸载详解!希望对大家会有帮助!有需要的朋友一起去看看吧 ...

    sanyao12074912019-11-06
  • SolarisSolaris8安装OPENSSH方法

    Solaris8安装OPENSSH方法

    Solaris8安装OPENSSH方法...

    Solaris教程网4112019-11-19
  • SolarisSolaris10.0下挂载光驱

    Solaris10.0下挂载光驱

    Solaris10.0下挂载光驱...

    Solaris教程网3882019-11-07
  • SolarisSolaris 基础知识

    Solaris 基础知识

    1. Q: Solaris 的系统配置文件一般在什么地方? A: 可以查看/etc/system文件,里面有一些solaris启动时默认加载的选项,包括 共享内存大小等的设置。 2. Q: 在sol...

    Solaris教程网3272019-11-20